Optimized Control Logic:
Adaptive operation and adaptive defrosting.
About NANCENT
Find out more about Nancent
Driven by R&D,
powered by expertise
Heal the planet,
one home at a time
Factory Tour
Products
Get your ultimate
cold therapy solution
Elevate your spa experience
to new heights
Elevate your pool experience
Experience the future
of home comfort
The smart, efficient way
to heat your water
Services
Complete service
from start to finish
Fast, regional support
Tailored solutions
for specific needs
Quick answers
to common questions
Experience optimal home comfort with our advanced heat pump, designed for energy efficiency, whisper-quiet operation, and a reduced carbon footprint.
Optimized Control Logic:
Adaptive operation and adaptive defrosting.
Ultra-Quiet Operation:
Sound pressure level of 40dB(A) - 50dB(A).
Comprehensive Explosion-Proof Design:
Ensures safety in various environments.
Parameters
Mode: NF- | 80HR2-ID | 120HR2-ID | 160HR2-ID | 120HR2-TID | 160HR2-TID | 200HR2-TID |
Prated Capacity (KW) For SCOP Average Climate | 6.34 | 8.89 | 12.11 | 8.89 | 12.11 | 17.07 |
Pmax Capacity(KW) 7/6 30°C/35°C | 8.05 | 12.01 | 16.03 | 12.01 | 16.03 | 20.01 |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C. | ||||||
Heating Capacity (kW) | 1.72~6.35 | 2.41~8.91 | 3.29~12.13 | 2.41~8.91 | 3.29~12.13 | 4.64~17.1 |
Power Input (kW) | 0.27~1.24 | 0.38~1.75 | 0.53~2.42 | 0.38~1.75 | 0.53~2.42 | 0.74~3.4 |
COP | 6.38~5.13 | 6.32~5.08 | 6.24~5.02 | 6.32~5.08 | 6.24~5.02 | 6.26~5.03 |
[Space Heating] Ambient Temp. (DB/WB): 2 °C/ 1 °C, Water Temp. (Inlet/Outlet): 30°C/35°C. | ||||||
Heating Capacity (kW) | 1.46~6.36 | 2.05~8.93 | 2.79~12.15 | 2.05~8.93 | 2.79~12.15 | 3.94~17.13 |
Power Input (kW) | 0.25~1.36 | 0.36~1.93 | 0.49~2.66 | 0.36~1.93 | 0.49~2.66 | 0.69~3.74 |
COP | 5.81~4.67 | 5.75~4.62 | 5.68~4.57 | 5.75~4.62 | 5.68~4.57 | 5.7~4.58 |
[Space Heating] Ambient Temp. (DB/WB): - 7°C/ - 8°C, Water Temp. (Inlet/Outlet): 30°C/35°C. | ||||||
Heating Capacity (kW) | 0.95~5.57 | 1.33~7.81 | 1.81~10.63 | 1.33~7.81 | 1.81~10.63 | 2.55~14.99 |
Power Input (kW) | 0.22~1.63 | 0.32~2.31 | 0.44~3.19 | 0.32~2.31 | 0.44~3.19 | 0.61~4.48 |
COP | 4.24~3.41 | 4.2~3.38 | 4.15~3.34 | 4.2~3.38 | 4.15~3.34 | 4.16~3.34 |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 40°C/45°C. | ||||||
Heating Capacity (kW) | 1.65~6.1 | 2.32~8.55 | 3.16~11.64 | 2.32~8.55 | 3.16~11.64 | 4.45~16.42 |
Power Input (kW) | 0.34~1.54 | 0.48~2.19 | 0.66~3.01 | 0.48~2.19 | 0.66~3.01 | 0.92~4.24 |
COP | 4.91~3.95 | 4.87~3.91 | 4.81~3.87 | 4.87~3.91 | 4.81~3.87 | 4.82~3.87 |
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 47°C/55°C. | ||||||
Heating Capacity (kW) | 1.6~5.91 | 2.25~8.3 | 3.06~11.3 | 2.25~8.3 | 3.06~11.3 | 4.32~15.92 |
Power Input (kW) | 0.37~1.71 | 0.53~2.42 | 0.73~3.33 | 0.53~2.42 | 0.73~3.33 | 1.02~4.69 |
COP | 4.31~3.46 | 4.27~3.43 | 4.22~3.39 | 4.27~3.43 | 4.22~3.39 | 4.23~3.4 |
[Space Cooling] Ambient Temp. (DB/WB): 35°C / 24, Water Temp. (Inlet/Outlet): 23°C/18°C. | ||||||
Cooling Capacity (kW) | 2~7.37 | 2.8~10.34 | 3.81~14.07 | 2.8~10.34 | 3.81~14.07 | 5.38~19.84 |
Power Input (kW) | 0.29~1.34 | 0.41~1.9 | 0.57~2.62 | 0.41~1.9 | 0.57~2.62 | 0.8~3.69 |
EER | 6.83~5.49 | 6.76~5.44 | 6.68~5.37 | 6.76~5.44 | 6.68~5.37 | 6.7~5.38 |
[Space Cooling] Ambient Temp. (DB/WB): 35°C / 24, Water Temp. (Inlet/Outlet): 12°C/7°C. | ||||||
Cooling Capacity (kW) | 1.7~6.29 | 2.39~8.82 | 3.25~12.01 | 2.39~8.82 | 3.25~12.01 | 4.59~16.93 |
Power Input (kW) | 0.44~2.05 | 0.63~2.99 | 0.86~4.18 | 0.63~2.99 | 0.86~4.18 | 1.21~6.36 |
EER | 3.85~3.07 | 3.82~2.95 | 3.77~2.87 | 3.82~2.95 | 3.77~2.87 | 3.78~2.66 |
[Hot Water] Ambient Temp. (DB/WB): 20°C/15°C, Water Temp. from 15°C to 55°C. | ||||||
Heating Capacity (kW) | 6.72 | 9.43 | 12.83 | 9.43 | 12.83 | 18.09 |
Power Input (kW) | 1.39 | 1.98 | 2.74 | 1.98 | 2.74 | 3.83 |
COP | 4.83 | 4.77 | 4.69 | 4.77 | 4.69 | 4.72 |
Max. Power Input (kW) | 2.48 | 3.51 | 4.83 | 3.51 | 4.83 | 6.80 |
Max. Running Current (A) | 10.76 | 15.25 | 21.01 | 5.96 | 8.21 | 11.55 |
Max. Outlet Water Temperature (°C) | 75 | |||||
Heating Operating Ambient Temp. Range (℃) | -25~45 | |||||
Cooling Operating Ambient Temp. Range (℃) | 15~48 | |||||
Power Supply | 220-2410V~/ 50Hz | 380-415V/3N~/ 50Hz | ||||
Rated Water Flow (m³/h) | 1.09 | 1.53 | 2.09 | 1.53 | 2.09 | 2.94 |
Water Pressure Drop (kPa) | 15 | 22 | 30 | 22 | 30 | 52 |
Expansion Tank (L) | 2 | 2 | 2 | 2 | 2 | 5 |
Compressor Brand | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi |
Circulating Pump Brand | GRUNDFOS | GRUNDFOS | GRUNDFOS | GRUNDFOS | GRUNDFOS | GRUNDFOS |
Fan Quantity | 1 | 2 | ||||
Display | 4-inch Color Touch Screen/7-inch Color Touch Screen | |||||
Wi-Fi Function | YES | |||||
ErP Level (35°C) | A+++ | |||||
ErP Level (55°C) | A+++ | A+++ | A+++ | A+++ | A++ | A+++ |
Refrigerant Type | R290 | |||||
Sound Pressure Level dB(A) at 1m | 33~40 | 34~42 | 35~43 | 34~42 | 35~43 | 37~45 |
Sound Power Level dB(A) | 48~55 | 49~57 | 50~58 | 49~57 | 50~58 | 52~60 |
Water Pipe Connection (inch) | G1 1/4" | |||||
Water Proof Class | IPX4 | |||||
Electricity Shock Proof | Ⅰ | |||||
Net Weight(kg) | 163 | 167 | 172 | 167 | 172 | 206 |
Net Dimensions (L*W*H) (mm) | 1381*460*920 | 1227*480*1470 | ||||